Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

Product Details
Customization: Available
After-sales Service: Free Technical Support and Training, 24h Online
Warranty: One Year Warranty and Long Life Maintenance
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
  • Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
ETCR-3200C
Display Type
Digital Only
Certification
RoHS, CE
Customized
Customized
Supplier
Lucyelec Test Equipment Co., Ltd.
Main Application
on-Site Measurement of Grounding Resistance, Soil
Multifunction
Grounding, Soil Resistivity, AC Current and DC Res
Power Supply
DC 7.4V 2600mAh Rechargeable Lithium Battery
Current Clamp
2PCS,1 Blue-Black Plug and 1 Red-Black Plug
Transport Package
Standard Export Package
Specification
280mm(L) X 260mm(W) X 160mm(H)
Trademark
Lucyelec
Origin
Baoding China
HS Code
9030332000
Production Capacity
1000pieces / Month

Packaging & Delivery

Package Size
35.00cm * 30.00cm * 20.00cm
Package Gross Weight
10.000kg

Product Description

Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
Product Description

ETCR3200C Double Clamp Multi-function Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can deal with all kinds of test requirements, can measure the grounding resistance value of the large size ground down lead, flexible measuring the grounding resistance value of the single point and grid grouding and all kinds of complex grounding structure, no need to disconnect any parallel connection earth pole when measuring parallel grounding system, greatly improves the convenience of measurement, for the grounding performance test provides a perfect solution.

ETCR3200C Double Clamp Multi-function Earth Resistance Tester is composed of host machine, current clamp(double clamp), test wires, auxiliary ground rod, data software and communication wires and so on. The large LCD display of host machine with white backlight and bar graph indication that can be seen clearly. The tester has storage function, clock function, and automatically stores 2000 groups of test results containing date and time.The tester with Bluetooth communication function supporting Android system. After the installation of APP, can test or read test records in the mobile terminal, bringing  a new experience. The tester equip USB interface, and the stored data can be uploaded to the PC through the USB interface. The communication software can realize the functions of reading, consulting, saving, reporting and printing of the historical record data. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment.

ETCR3200C Double Clamp Multi-function Earth Resistance Tester performance feature:

1.1.Unique design of the jack indicator light, accurate indication of the jack position, avoid operation error.
1.2.12 gears function selection knob, various test methods are displayed, making the operation simple and fast.
1.3.The tester has Bluetooth communication function and supports Android system. Users can use mobile terminal to test operation or read test results containing date and time very conveniently.
1.4.The instrument case adopts waterproof protection box, which is strong, safe and durable for anti-collision, anti-fall and waterproof (protection grade IP65), especially suitable for use in outdoor construction sites.
1.5.The meter is equipped with large capacity rechargeable lithium battery pack. And with USB interface to upload data function.
Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

Product Parameters

1. Base Conditions and Working Conditions

Influence Quantity Base Condition Working Conditions Remark
Ambient Temp 23ºC±1ºC -10ºC~40ºC ----
Ambient Humidity 40%-60% <80% ----
Working Voltage 7.8V±0.1V DC 7.8V±0.6V ----
Auxiliary Earth Resistance <100Ω <5kΩ  
Interference Voltage Should avoid <20V  
Interference Current Should avoid <2A  
Electrode Distance when  measuring R a>5d a>5d  
Electrode Distance when  measuring ρ a>20h a>20h  

2. General specification

Function Measure grounding resistance, soil resistivity; DC resistance, earth voltage, alternating current , leakage current
Power Supply DC 7.4V 2600mAh rechargeable lithium battery, full of about 8.4V
Backlight Controllable screen backlight, suitable for dim places
Measuring Method DC resistance DC resistance 2-wire method
DC resistance 4-wire method
Earth resistance Earth resistance 2-wire method
Earth resistance 3-wire method
Earth resistance 4-wire method
Earth resistance single clamp 3-wire method (selection method)
Earth resistance single clamp 4-wire method (selection method)
Earth resistance doule clamp method
Soil resistivity(Wenner method)
Earth current Current clamp measurement
Earth voltage Average rectification
Test Voltage Wave Sine wave
Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current AC 250mA max
Open-circuit Test Current AC 40V max
Electrode Distance Range 1m-100m
Display Mode 4-digital large LCD display, with screen backlight
Measuring Indicator During measurement, LED flash indicator, LCD countdown display
LCD Frame Dimension 128mmX75mm
LCD display area 124mmX67mm
Instrument Dimension 280mm(L) X 260mm(W) X 160mm(H)
CT Size 223mm X 120mm X 39mm
Test Wire 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire 2 wires: each for red 1.6m and black 1.6m
Auxiliary Grounding Rod 4PCS: Φ10mm X150mm
Current Clamp 2PCS :1 blue-black plug and 1 red-black plug
Clamp Caliber Φ70mm
Clamp Lead Wire 2m
Measuring Rate AC current: about 2 times/second
Earth Voltage: about 2 times/second
Earth resistance: about 7 seconds/time
Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Line Voltage Measurement below AC 600V
Communication Interface Bluetooth module, USB interface, storage data can be uploaded to computer, saved or printed.
Communication Wire USB communication wire X1pcs, with length 1.5m
Data Hold Data hold function: "HOLD" symbol display
Data Storage 2000 groups, "MEM" storage indicator, "FULL" symbol flash display storage is full
Data Access Data read function: "READ" symbol display
Overflow Display Exceed measuring range overflow function: "OL" symbol display
Low Current Indicator of Current clamp Measurement with selection method or double clamp, the current signal received by CT2 is lower than 0.5mA,will display"    ", and should check the clamping direction of the CT2 current clamp
Interference Test Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V
Auxiliary Grounding Test With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function Measuring value exceeds alarm setting value, will make out "Toot-toot-toot" alarm sound.
Battery Voltage While battery voltage decreases to around 7.2V±0.1V, will display battery voltage low symbol"     ", and reminding to replace the battery
Automatic Shutdown Automatically shut down after 15 minutes of power on
Working Current Backlight: 25mA Max(only backlight power consumption)
Standby:25mA Max(Backlight off after power on)
Measurement:150mA Max(Backlight shut off)
Weight Tester: 2290g
Current Clamp:1100g(2pcs)
Total weight: 6800g(include all accessories)
Working Temperature & Humidity -10ºC~40ºC, below 80%RH
Storage temperature & humidity -20ºC~60ºC, below 70%RH
Protection Level IP65(close the case)
Overload Protection Measure earth resistance: between each interfaces of C(H)-E, P(S)-ES,AC 280V/3 seconds
Insulation Resistance Over 20MΩ(between circuit and outside shell is 500V)
Withstanding Voltage AC 3700V/rms. (Between circuit and outside shell)
Electromagnetic Features IEC61326(EMC)
Protection Type IEC61010-1(CAT 300V, CAT IV 150V, Pollution 2);
IEC61010-031;
IEC61557-1(Earth resistance);
IEC61557-5(Soil resistivity);
JJG 366-2004(Grounding resistance meter)
JJG 1054-2009(Clamp grounding resistance meter)

3. Intrinsic error and performance indicators under base conditions

Measurement Function Measurement Range Accuracy Resolution
2/3/4-wire method measure earth resistance(R~)     
DC resistance(R--)
0.000Ω~9.999Ω ±2%rdg±0.05Ω 0.001Ω
10.0Ω~29.99Ω ±2%rdg±5dgt 0.01Ω
30.0Ω~299.9Ω ±2%rdg±3dgt 0.1Ω
300kΩ~2999kΩ ±2%rdg±3dgt
3.00kΩ~300.00kΩ ±4%rdg±3dgt 10Ω
Selection method  measure earth resistance(Re) 0.000Ω~9.999Ω ±2%rdg±0.05Ω 0.001Ω
10.00Ω~29.99Ω ±2%rdg±5dgt 0.01Ω
30.0Ω~299.9Ω ±2%rdg±3dgt 0.1Ω
300Ω~3000Ω ±2%rdg±3dgt
Double clamp method measure grounding resistance(R~) 0.01Ω~0.99Ω ±10%rdg±5dgt 0.01Ω
1.0Ω~29.9Ω 0.1Ω
30Ω~100Ω
Soil Resistivity (ρ)
 
0.00Ωm~99.99Ωm According to the measurement accuracy
(ρ=2πaR
a:1 m~100m;
π=3.14)
0.01Ωm
100.0Ωm~999.9Ωm 0.1Ωm
1000Ωm~9999Ωm 1Ωm
10.00kΩm~99.99kΩm 10Ωm
100.0kΩm~999.9kΩm 100Ωm
1000kΩm~9000kΩm 1kΩm
Earth Interference Voltage (V~) (50Hz/60Hz) AC 0.0~100V ±2%rdg±3dgt 0.1V
AC Interference current (V~)(50Hz/60Hz) AC 0.0mA~600.0A ±2%rdg±3dgt 0.01mA

Note: 1.rC max or rPmax: additive error≤±5%rdg±5dgt
(rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ)

 

Detailed Photos

Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

3.1. USB interface    3.2. Charge interface 
3.3. E interface (earth pole) 3.4. ES interface (Auxiliary earth pole)
3.5. P(s) interface (voltage pole)  3.6. C (H) interface (current pole)
3.7. C1 interface (dotted terminal of CT2)  3.8. C2  interface (public interface of CT2)
3.9. Interface indicator    3.10. Test button
3.11. LCD display screen 3.12. Function selection rotary knob
3.13. Function button area   3.14. Stimulant current clamp CT1
3.15. Stimulant current clamp CT1 connecting interface, red banana plug is dotted terminal, black is public terminal   3.16. Receive clamp CT2
 
3.17. Receive current clamp CT2 connecting interface, blue banana plug is dotted terminal,
black is public terminal
3.18. Simple test wires
3.19. Auxiliary grounding rod   3.20. Test wires
Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity TesterLucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
Certifications

Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity TesterLucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

Company Profile

Lucyelec Test Equipment Co., Ltd. engaged in oil Analysis and electrical test equipment since 2015, is your reliable partner and professional provider of test and measurement instruments in Baoding China.
Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

Main Products:

1. Oil Test kits (BDV, Tan Delta, Flash Point, Water content, Interfacial Tension, Gas Chromatography, Kinematic Viscosity… etc)

2. Transformer testers /CT PT analyzer (TTR, Winding resistance, Winding deformation, Capacitance and tan delta test, Partial dicharge, etc)

3. SF6 Gas Analyzers (Dew point, Purity, Compensation, etc)

4. Switch/Circuit breaker analyzers (Contact resistance, Mechanical characteristics)

5. MOA/Insulator test devices

6. HV Hipot Testers (AC/DC/VLF)

7. Insulation/Earth resistance test

8. Secondary Injection Relay Test Sets

9. Cable fault location system

10. DC System/Battery Testers

11. Electric safety tools and test equipments

Lucyelec Test Equipment Factory Workshops:

Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester
Lucyelec Double Clamp Multifunction Ground Resistance and Soil Resistivity Tester

If you have any inquiry about quotation or cooperation, please contact Lucyelec. Our sales representative will reply you within 24 hours. Thank you for your interest in our products.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier