Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Product Details
Customization: Available
After-sales Service: Free Technical Support and Training, 24h Online
Warranty: One Year Warranty and Long Life Maintenance
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
  • Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Hotsale Transformer Oil Tester
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
DDF-2000A
Display
Digital
Control
Automatic Control
Weight
0-100Kg
Power Source
AC220V
Supplier
Lucyelec Test Equipment Co., Ltd.
Functions
Dissipation Factor Transformer Oil Analysis
Test Standard
ASTM D924; ASTM D1169
Capacitance Measuring Range
5PF~200PF
Relative Pemitivity
1.000-30.000
Dielectric Loss Factor
0.00001-100
DC Resistivity
2.5 MΩm-20 TΩm
Temperature Range
0-120 Degree
Power Supply
220V 50Hz (Customized)
Aftersales Service
Yes
OEM/ODM Service
Yes
Auto-Drain Facility
Yes
Transport Package
Standard Export Package
Trademark
Lucyelec
Origin
Baoding China
HS Code
9031809090
Production Capacity
500pieces / Month

Packaging & Delivery

Package Size
43.00cm * 35.00cm * 42.00cm
Package Gross Weight
35.000kg

Product Description

Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
Product Description

General Descriptions:

Automatic Insulating oil tan delta and resistivity tester,also called High Precision Oil Dissipation Factor Tester or oil tangent delta tester, which is used for testing dielectric dissipation factor (tangent delta value), relative permittivity and DC volume resistivity of insulating liquids.

The instrument is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge,AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. It is equipped with large colorful touch screen LCD display. The test results can be automatically stored and printed out so that the operator with no professional training will be able to use it easily.
 

Technical Specification

Measuring range Capacitance:5pF~200pF

Relative permittivity: 1.000-30.000

Dielectric loss factor: 0.00001-100

DC resistivity: 2.5 MΩm-20 TΩm

Measurement accuracy Capacitance: ± (1% reading + 0.5pF)

Relative permittivity: ±1% reading

Dielectric loss factor ± (1% reading + 0.0001)

DC resistivity: ±10% reading

Resolution Capacitance: 0.01pF

Relative permittivity: 0.001

Dielectric loss factor: 0.00001

Temperature range 0-125 °C
Temperature measurement error ±0.5 °C
AC experimental voltage 0-2200V,continuously adjustable, frequency: 50Hz
DC test voltage 0-500V, continuously adjustable
Power consumption 100W
Power supply voltage AC 220V ± 10%(can be customized)
Power frequency

Ambient temperature

50Hz/60Hz ±1%

0-40 °C

Relative humidity ≤80%
Dimensions 420 × 380 × 385mm
Weight 21kgs

Features and Advantages:

  • With microcomputer control, automatically complete the whole process including heating, temperature controlling, voltage rising, high-speed data sampling and calculating, display, print and storage test results. Fully auto-measurement, high precision and fast speed.
  • Oil vessel with three-electrode structure design, electrodes space 2mm, it can eliminate stray capacitance and leakage effects on dielectric loss test results.
  • Instrument adopts the medium frequency induction heater and PID temperature controller. It means that there is uniformity of temperature throughout the cell.
  • Inbuilt standard capacitor, the dielectric loss and capacitance of the capacitor will not be affected by ambient temperature, humidity, etc., so that the accuracy of the instrument can be guaranteed even after long-term use.
  • 7 inch colorful touch screen with adjustable brightness. Easy operation and human-friendly. Perfect protection and warmly reminding functions. There is over voltage, over current or high-voltage short circuit, instrument can quickly cut off and issues a warning sign. When the temperature of the sensor fails or is not connected, the instrument will also issue a warning message.
  • Instrument with blank calibration function. Measuring the capacitance and dielectric loss factor of empty electrode cup is to judge the cleanness and assembly condition of oil vessel. Calibration data automatically saved is to facilitate accurate calculation of relative permittivity and DC resistivity.
  • Built-in real-time clock, display current time, date, and can be print out together with test results. Equipment can display the ambient temperature, real-time detect the environment.
  • Auto-storage function. Can store data up to 100groups.
  • Can connect to PC by USB/RS232 or Wireless transmission function. (Optional)
Detailed Photos

Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis InstrumentInsulating Oil Dissipation Factor and DC Resistivity Measurement
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis InstrumentLucyelec aims to provide diversified oil analysis instrument for worldwide cusotmers. 
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Hotsale Transformer Oil Tester
 
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
IEC60156 Dielectric Strength Insulating Oil Portable BDV Measuring Kit
Model: BDV-801H, Output 0-70kV, built-in battery, compact and portable, suitable for transformer field testing

Voltage Boost speed:
0.5kV/s-5.0kV/s (increasing every 0.5kV/s), 10 gears option, Error 0.2kV/s
Electrode gap: standard 2.5 mm
Number of tests:6 times (1-10 times optional)
Rest time: 900S (optional from 0 to 5900 S)
Interval time: 300S (optional from 0-5900S)
Stiring time:15S (0-240S optional or on/off)
Display: Large screen LCD display

Lab Analysis Instrument Transformer Oil Moisture Content Meter Coulometric Karl Fischer Titrator

Model: KF106C
Titration method:Coulometric titration
Testing scope: 
0ug~200mg (10µg~100µg typical value)
Electrolysis Current:0~400mA
Sensitivity: 0.1µg
Precision: 5µg~100µg ±3µg
3% above 100
µg (not including sampling error)
Specimen form: solid, liquid and gas
Display: Color LCD screen
Data storage: 1000 testing results can be stored
Status indicator:  dynamic curve, text display
Agitation speed control:  sliding touch control panel
Duration: 10 years with power down
Printer:   Thermal printer 
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Please contact Lucyelec for more Transformer Oil Laboratory Analysis Instruments

Certifications

Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis InstrumentInsulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Company Profile

Lucyelec Test Equipment Co., Ltd. engaged in oil Analysis and electrical test equipment since 2015, is your reliable partner and professional provider of test and measurement instruments in Baoding China.
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Main Products:

1. Oil Test kits (BDV, Tan Delta, Flash Point, Water content, Interfacial Tension, Gas Chromatography, Kinematic Viscosity… etc)

2. Transformer testers /CT PT analyzer (TTR, Winding resistance, Winding deformation, Capacitance and tan delta test, Partial dicharge, etc)

3. SF6 Gas Analyzers (Dew point, Purity, Compensation, etc)

4. Switch/Circuit breaker analyzers (Contact resistance, Mechanical characteristics)

5. MOA/Insulator test devices

6. HV Hipot Testers (AC/DC/VLF)

7. Insulation/Earth resistance test

8. Secondary Injection Relay Test Sets

9. Cable fault location system

10. DC System/Battery Testers

11. Electric safety tools and test equipments

Lucyelec Test Equipment Factory Showroom:
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument
Lucyelec Customer Visit:
Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

If you have any inquiry about quotation or cooperation, please contact Lucyelec. Our sales representative will reply you within 24 hours. Thank you for your interest in our products.

Insulating Oil Dielectric Dissipation Factor Transformer Oil Laboratory Analysis Instrument

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier