Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

Product Details
Customization: Available
After-sales Service: Free Technical Support and Training, 24h Online
Warranty: One Year Warranty Long Time Maintenance
Manufacturer/Factory, Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
  • Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
KF-106C
Analysis Method
Chemical Analysis
Display
Digital
Application
Transformer Oil Moisture Content Analyzer
Portable
Portable
Chemical Analysis Type
Karl Fischer Method
Operating Mode
Touch Screen
Off Mode
Manual
Supplier
Lucyelec Test Equipment Co., Ltd.
Test Method
Coulometric Titration Method
Measuring Range
200mg
Electrolysis Current
0~400mA
Advantages
High Accuracy and Stable Performancee
Customized Service
Yes
Technical Support and Training
Yes
Aftersales Service
Yes
Power Supply
AC220V 50Hz
Transport Package
Standard Export Package
Trademark
Lucyelec
Origin
Baoding China
HS Code
9031809090
Production Capacity
500pieces / Month

Product Description

Lucyelec Water in Oil Analysis Instrument KF106C Moisture Content Coulometric Karl Fischer Titrator
Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
Product Description

Descriptions:

KF106C Karl Fischer Titrator is a new developed micro moisture measurement and analysis apparatus with high-resolution color touch LCD, convenient and visual HMI and operability. The apparatus adopts high performance ARM processor, which has large data storage, fast and stable operation and outstanding anti-disturbance performance, has the advantages of high detection speed and high precision. The instrument has (i) self-diagnosis of trouble function, display and print the results when the test finished; (ii) measuring dynamic curve indicating function which makes the test more intuitive; (iii) large data storage function which could up to 1000 data records; (iiii) delay measuring function, which is very effective in the testing of lower moisture content of specimen. The instrument adopts the sliding touch stirring to control the speed; Moisture content calculation formula contains various algorithms that based on the volume and weight etc.; During the testing, people could modify the related parameters of the formula timely and will not affect the measurement value of moisture content which is convenient to the user.
The instrument adopts Karl-Fischer coulomb titration method to determine the moisture content of the liquid, gas and solid sample reliably. During the test, the instrument will make indirect measurement with corresponding sample injector of solid, gas and liquid to the solid of insoluble to the reagent and material that will pollute the electrode and affect reagent reacting, therefore, it is a kind of highly efficient, fully automatic analysis instrument which will be widely used in electric power, petroleum, chemical industry, medicine, railway, environmental protection, scientific research institutions and other industries.

Working Theory
Equation of Karl Fischer reagent and water is as follows:
I2+SO2+3O5H5N+H2O-2C5H5N·HI+C5H5N·SO3······(1)
C5H5N·SO3+CH3OH-C5H5N·HSO4CH3·············(2)
The reagent solution is composed by the majority iodine, pyridine with sulfur dioxide and carbinol etc.   Iodine is formed through electrolyzing at anode.  According to Faraday's Law, iodine is in the direct ratio with quality of electric charge.  The equation is as follows:
2I¯-2e-I2······   (3)
From (1), molecules of iodine are equal to molecules of water.  Put the sample in Karl Fischer reagent, water in the sample consumes iodine in the reagent. The instrument can display the consumption of iodine during the titration. The iodine consumption is in the ratio with the quantity of electric charge.  The moisture content is decided by the quantity of electric charge.  This instrument adopts automatic electrolysis current controlling system. The electrolysis current can be decided by the water content of the sample, the maximum is 400mA.

Product Parameters

Technical Specification
Titration method:       Coulometric titration
Testing scope:          0ug~200mg (10µg~100µg typical value)
Electrolysis Current:     0~400mA
Sensitivity:            0.1µg
Precision:             5µg~100µg ±3µg
3% above 100µg (not including sampling error)
Specimen form:         solid, liquid and gas
Display:              Color LCD monitor
Controlling:           Touch screen
Data storage:              1000 testing results can be stored 
Status indicator:           dynamic curve, text display
Agitation speed control:     sliding touch control panel 
Duration:                10 years with power down
Printer:                    Thermal printer 
Power supply:              AC220V±11V  50Hz±2.5Hz
Power:                    ≤50VA
Environment temperature:     5ºC-35ºC
Environment humidity:        ≤85%RH 
Dimension:                 330mm X 240mm X 180mm
Weight:                    about 10Kg
 

Detailed Photos

Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer TitratorLucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

Certifications

Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer TitratorLucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

Company Profile

Lucyelec Test Equipment Co., Ltd. engaged in oil Analysis and electrical test equipment since 2015, is your reliable partner and professional provider of test and measurement instruments in Baoding China.
Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

Main Products:

1. Oil Test kits (BDV, Tan Delta, Flash Point, Water content, Interfacial Tension, Gas Chromatography, Kinematic Viscosity… etc)

2. Transformer testers /CT PT analyzer (TTR, Winding resistance, Winding deformation, Capacitance and tan delta test, Partial dicharge, etc)

3. SF6 Gas Analyzers (Dew point, Purity, Compensation, etc)

4. Switch/Circuit breaker analyzers (Contact resistance, Mechanical characteristics)

5. MOA/Insulator test devices

6. HV Hipot Testers (AC/DC/VLF)

7. Insulation/Earth resistance test

8. Secondary Injection Relay Test Sets

9. Cable fault location system

10. DC System/Battery Testers

11. Electric safety tools and test equipments

Lucyelec Test Equipment Factory Workshops:

Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
Lucyelec Customer Visit:

Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator
Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

If you have any inquiry about quotation or cooperation, please contact Lucyelec. Our sales representative will reply you within 24 hours. Thank you for your interest in our products.
Lucyelec Water in Oil Analysis Instrument Kf106c Moisture Content Coulometric Karl Fischer Titrator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier