Secondary Current Injection Test Set Three Phase Relay Protection Tester

Product Details
Customization: Available
After-sales Service: Free Technical Support and Training, 24h Online
Warranty: One Year Warranty and Long Life Maintenance
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • More Transformer Test Kits
Overview

Basic Info.

Type
Secondary Current Injection Test Set
Accuracy Grade
0.2
Display
Digital
Control
Computer Control
Power Source
AC220V
Supplier
Lucyelec Test Equipment Co., Ltd.
Current Output (Effective Value)
0~40A AC Output
Accuracy
0.2
DC Current Output
0~±10A/Phase,0~±30A/3 Parallel
AC Voltage Output
0~120V Precision 0.2
DC Voltage Output
0~±160V Precision 0.5
Technical Support
Yes
Transport Package
Standard Export Package
Specification
54*35*67cm
Trademark
Lucyelec
Origin
Baoding China
HS Code
9030820000
Production Capacity
800pieces / Month

Packaging & Delivery

Package Size
54.00cm * 35.00cm * 67.00cm
Package Gross Weight
30.000kg

Product Description

Secondary Current Injection Test Set Three Phase Relay Protection Tester
Model: DCJB-702
Secondary Current Injection Test Set Three Phase Relay Protection Tester
Product Description

Section 1   Hardware Structure


¿ High-Performance Industrial Control Computer
High performance Industrial control computer is adopted as the controlling computer, through which you can run the windows operating system directly. 6.4"TFT true color LCD display, tracking ball and optimized keyboard are allocated on the faceplate of this tester, which can be used without the external mouse and keyboard. USB interface, 10-100M net mouth and serial communication interface are located on the back plate of this tester, through which you can access data, communicate data and upgrade software conveniently.
The whole process and the result of the test will all be showed on the LCD. The English operational interface of the complete set is very friendly and convenient. The tracking ball and keyboard on the faceplate will implement the operation. The operation is simple and convenient, and is easy to be mastered. Operator only needs a little knowledge of computer.
Keyboard and mouse interface are also allocated on the faceplate. If you would like to use the external mouse and keyboard, through pluging them with corresponding interfaces, you can operate this tester just like operate a desk-top computer.
¿ Digital Signal Processor Microcomputer
High-speed digital controlling processor is adopted as the output core of the tester. 32 bit double precision arithmetic is employed in the software, through which arbitrary high-accuracy waveforms of each phase can be produced. Since integrative structure is adopted,the structure of the tester is layed compactly.The distance of data transmission is short with tight structure, which overcome the problem of fewer points of waveform output due to long data communicational line and narrow frequency band when using the test controller controlled directly by PC.
¿ D/A Conversion and Low-Pass Filtering
High precision D/A converter is employed for ensuring the precision and linearity of current and voltage in the whole range.
Due to high density of fitting ponit, fidelity of waveform is high and harmonic component is small, which don't have a strict requirement on the low-pass filter. Consequently, it has good characteristics of transient, phase frequency and amplitude frequency, which is easy to perform accurate phase-shifting and harmonic superposition and ensures very high precision even when the frequency is high.
¿ Voltage and Current Amplifier
For phase current and voltage, we persist in adopting high performance linear amplifier output mode in order to make the current and voltage source to directly output all kinds of waveforms from the DC waveform to the waveforms including all kinds of frequency components, such as square wave, combined waveform overlapped by each order harmonic, fault transient waveform, etc. In addition, the output waveform is clear and smooth without high-frequency radiated interference with neighboring equipments. It can simulate well all kinds of current and voltage characteristics under the circumstance of short circuit fault.
For power amplifier circuit, we adopt import power parts with high-power and hi-fi module style as power output, combining with heat dissipation structure layed elaborately and reasonably, it has enough large power redundancy and thermal capacity. The power amplifier circuit has overheat, overflow, overvoltage and short circuit protections. When overflow occurs in the current circuit and overload or short circuit occurs in the voltage circuit, it will limit the output power automatically, switch off the whole power amplifier circuit and give alarm signal.In order to prevent the overheat of the power amplifier for long time operating under large current, a software time terminating system under large current is set in this tester. It can work for a long period when outputting is 10A or below. When the current is over 10A, the tester will start up the software time termination order. When time is up, the software will forbid power output automatically and give alarm signal. The higher output current is, the shorter the limiting time will be.
¿ Digital Input and output
This tester has 10 channels digital input and 8 channels output.
The switching input circuit is compatible for both the empty contacts and 0-250V electric potential contacts in the input and output circuit. When the electric potential contacts are selected, 0-6V belongs to closed switch and 11-250V belongs to open switch. The switching capacity can test the action time and the action time interval of every phase switch's contact conveniently.
   The part of the digital input is isolated from the resources of the mainframe and the amplifier. The end of the digital input is hung, so the common end of the digital input is separated from the Common End UN, IN of current and voltage parts.
Switching potential input has directivity, you should connect the common end with the positive terminal of potential, and connecting the input end with negative terminal of potential for ensuring the potential of common end is higher than the one of input end. In practice, you should connect the input common end with +KM, and connecting the negative terminal of contact with input end.
The output part is the idle contact output of relay. Output capacity is DC:220V/0.2A,AC:220V/0.5A. Output of switching capacity is independent of voltage, current, input and all other parts. Action process of each digital output part is different in each testing module. For details, please refer to the operation instruction on software module.

Section 2  Instruction to Front and Rear Panel

¿ Instruction to Front panel of Device Relay Protection
Secondary Current Injection Test Set Three Phase Relay Protection Tester
1. Voltage and current output terminals
2. Switching input terminal
3. Switching output terminal
4. The trackball mouse can be used for process control during experiments; Equipped with left and right buttons on the trackball mouse; Panel optimization keyboard
5. 5-inch LCD display screen
6. GPS antenna
7. USB communication port, can be connected to an external computer for testing
8. USB interface, capable of connecting and communicating with external devices such as USB drives and printers
9. Independent DC power supply outputs positive
10. Independent DC power supply outputs negative
11. Independent DC power supply output switching switch
12. DC voltage output insurance
13. Grounding terminal
14. Power switch
15. 220V voltage input insurance
16. 220V power input three hole socket
Product Parameters

AC current output

Phase current output (effective value)
 
0~40A, Output Precision  0.2 degree
 
3 phase parallel current output (effective value)
 
0~120A
 
A Long-time Phase current
 
10A
 
Maximum output power of Phase current
 
450VA
 
Maximum output power of 3 parallel current
 
900VA
 
Maximum Permitted work time of 3 parallel current
 
10S
 
Frequency range ( fundamental)
 
0~1000Hz
 
Harmonic time
 
0~20
 

DC current output
Current output  
 
0~±10A /Phase, 0~±30A / 3 parallel
 
Output Precision
 
0.5 degree

AC voltage output
Phase voltage output (effective value)
 
0~120V   Output Precision   0.2 degree
 
Line voltage output (effective value)
 
 0~240V
 
Phase voltage / Line phase output power
 
80VA / 100VA
 
Frequency range (fundamental)
 
0~1000Hz
 
Harmonic time
 
 0~20
 

DC voltage output
Phase voltage output range
 
0~±160V     Output Precision  0.5 degree
 
Line voltage output range
 
0~±320V
 
Phase voltage / Line phase output power
 
70VA / 140VA
 
                                          
10 path digital input and 8 path digital output
Time measuring range
 
0.1ms ~ 9999s ,accuracy of measurement <0.1ms
 
Packaging & Shipping

Secondary Current Injection Test Set Three Phase Relay Protection TesterSecondary Current Injection Test Set Three Phase Relay Protection Tester

Secondary Current Injection Test Set Three Phase Relay Protection Tester
Company Profile

Lucyelec Test Equipment Co., Ltd. engaged in oil Analysis and electrical test equipment since 2015, is your reliable partner and professional provider of test and measurement instruments in Baoding China.
Secondary Current Injection Test Set Three Phase Relay Protection Tester

Main Products:

1. Oil Test kits (BDV, Tan Delta, Flash Point, Water content, Interfacial Tension, Gas Chromatography, Kinematic Viscosity… etc)

2. Transformer testers /CT PT analyzer (TTR, Winding resistance, Winding deformation, Capacitance and tan delta test, Partial dicharge, etc)

3. SF6 Gas Analyzers (Dew point, Purity, Compensation, etc)

4. Switch/Circuit breaker analyzers (Contact resistance, Mechanical characteristics)

5. MOA/Insulator test devices

6. HV Hipot Testers (AC/DC/VLF)

7. Insulation/Earth resistance test

8. Secondary Injection Relay Test Sets

9. Cable fault location system

10. DC System/Battery Testers

11. Electric safety tools and test equipments

Secondary Current Injection Test Set Three Phase Relay Protection Tester

 

More Transformer Test Kits

More Test Equipments for Transformer, please click the image for more details
 

Secondary Current Injection Test Set Three Phase Relay Protection Tester
Secondary Current Injection Test Set Three Phase Relay Protection Tester
Secondary Current Injection Test Set Three Phase Relay Protection Tester

If you have any inquiry about quotation or cooperation, please contact Lucyelec. Our sales representative will reply you within 24 hours. Thank you for your interest in our products.

Secondary Current Injection Test Set Three Phase Relay Protection Tester

       

    
                       
                   
                           
                                   

                           
                                         

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier